Atlanta, GA · 48,000 sq ft · built 2009

Northstar Business Center

Attention required

6 things need your attention

showing 3 of 6View all
01
CriticalSignal strong$26,500 estimated replacement

HVAC Unit #2 — likely loss of cooling capacity

What happened
Supply temperature and runtime are both rising at the same time. The unit is running longer and still delivering warmer air.
Why Rivet thinks so
Two independent measurements moved together, which distinguishes a capacity fault from a setpoint or occupancy change — a thermostat change would lower runtime, not raise it. This unit also has 3 recorded repairs, including prior refrigerant loss with no leak located.
Why it matters
Declining cooling capacity typically ends in compressor failure. Coverage may still apply, so the order of operations matters: verify before authorizing paid work.
What to do next
  • Request a diagnostic call — Ask the vendor for a full leak search and verification of refrigerant charge and compressor performance.
View evidence→Open asset
02
CriticalSignal strong

HVAC Unit #2 — daily runtime outside normal range

What happened
Reading has moved up 8.4 from a typical 11.5, and has stayed outside its normal range for 6 consecutive readings.
Why Rivet thinks so
Readings are 11.79 standard deviations from this unit's established baseline of 11.5 (typical variation ±0.7), and the deviation held across 6 consecutive readings rather than appearing as a single spike.
Why it matters
Sustained deviation in daily runtime usually precedes a service call. Catching it now is the difference between a scheduled inspection and an emergency response.
What to do next
  • Schedule an inspection — Have the unit assessed before the next scheduled service interval.
View evidence→Open asset
03
CriticalSignal strong

HVAC Unit #2 — supply temperature outside normal range

What happened
Reading has moved up 7.7 from a typical 70.6, and has stayed outside its normal range for 5 consecutive readings.
Why Rivet thinks so
Readings are 10.18 standard deviations from this unit's established baseline of 70.6 (typical variation ±0.8), and the deviation held across 5 consecutive readings rather than appearing as a single spike.
Why it matters
Sustained deviation in supply temperature usually precedes a service call. Catching it now is the difference between a scheduled inspection and an emergency response.
What to do next
  • Schedule an inspection — Have the unit assessed before the next scheduled service interval.
View evidence→Open asset

Building health

Assets tracked
8
4 operating nominally
Needs attention
4
Elevated or high replacement risk
Open findings
6
3 critical
Maintenance due
3
Within 14 days
Semi-annual service due

Capital exposure

5-year projected capital exposure
$7k–$12k+
Estimated range · low confidence
1 of 2 scheduled assets lacks a replacement-cost estimate — actual exposure is higher
2026
$7k–$12k
Water Heater
2027
—
2028
Unknown

Assets to watch

All assets
Main Electrical Panel
EP-1 · Square D QED-2
good
HVAC Unit #2
RTU-2 · Trane Precedent YSC060
fair
Water Heater
WH-1 · A.O. Smith BTH-199
poor

Recent activity

After-hours access — Office Floor 2
3d ago
Tenant complaint — inconsistent hot water
6d ago
Access Control System
2029
—
2030
—
Show assumptionsHide assumptions
  • Replacement timing projected from install date against category service-life medians, adjusted for condition and repair frequency.
  • Cost range reflects ±25% on recorded replacement estimates.
  • Figures are internal estimates, not vendor quotes.
  • 1 of 2 assets projected in this window have no replacement-cost estimate and are excluded from totals — actual exposure is higher.
  • A further 1 tracked assets have no replacement-cost estimate but fall outside this window.
Location added to Rivet
22d ago
Maintenance completed on HVAC Unit #1
59d ago